home *** CD-ROM | disk | FTP | other *** search
/ QRZ! Ham Radio 6 / QRZ Ham Radio Callsign Database - Volume 6.iso / pc / files / p_msys / msys117.exe / WHATSNEW.117 < prev    next >
Encoding:
Text File  |  1994-03-24  |  20.8 KB  |  603 lines

  1.  
  2.  
  3.  
  4.  
  5.                                 WHAT'S NEW in MSYS 1.17
  6.  
  7.            TO PROPERLY INSTALL MSYS 1.17 UPGRADE, you MUST have MSYS 1.16
  8.            fully installed.  That will require the 3 disk set of MSYS 1.16
  9.            which includes the full documentation.  The three disk set is
  10.            available from the sources listed on Page 9 of this document.
  11.  
  12.            1.  RLI compatible compression has been fixed.
  13.                Use the XO and NETXO options to implement.  Also, set XB and
  14.                NETXB parameters.
  15.                
  16.            2.  Automatic merge operation has been implemented.
  17.                When MSYS first starts, it will automatically merge the
  18.                MSYSFWD.DEF files with the  <bbs>.FWD/REV files to create the
  19.                MSYS.FWD file.  Merge can not be done while forwarding is in
  20.                progress, but MSYS will automatically perform the function at
  21.                the start of the next forward cycle if the MERGE command has
  22.                been given.
  23.                
  24.            3.  The IPADDR now can take the following forms:
  25.                44.70.4.6
  26.                [44.70.4.6]
  27.                
  28.            4.  A sysop may respond with a   K (without message number) as a
  29.                response to the Reply to this message? question, causing the
  30.                message to be deleted.  It is a useful addition in system
  31.                maintenance, especially if autoreply is turned on.
  32.                
  33.            5.  A new line has been added to the Sysop command "#" response
  34.                giving the numbers of various types of messages.
  35.                
  36.            6.  MSYS now supports higher IRQ's.  Of interest will be IRQ's
  37.                3,4,5,7,10,11,12, & 15.
  38.                
  39.            7.  MUTIL 20 now creates a NEW bbslist.dat.  No further need to
  40.                delete the old and rename the new one!
  41.                
  42.            8.  MSYS now uses close to 500K of EMS.
  43.                
  44.            9.  Many of the messages formerly stored within the program are
  45.                now in  MSYSMSGS.DAT
  46.  
  47.                MAKE SURE YOU PUT THE NEW MSYSMSGS.DAT file in your
  48.                MSYS\HELP\ directory!
  49.  
  50.  
  51.  
  52.  
  53.            10. MSYS.OPT has a new parameter:
  54.                netnode #neighbors #dests #circuits
  55.  
  56.                If used, the netnode number must contain all three numbers.
  57.                For example: netnode 25 100 10
  58.                would give 25 neighbor nodes, 100 destinations and 10
  59.                circuits (default).  This command has been added to permit
  60.                additional free memory for those systems that do not have a
  61.                large NetRom switching requirement while making provision for
  62.                those that do.  Obviously, the larger this list size, the
  63.                less room in MSYS for additional connects.
  64.  
  65.  
  66.                   MUTIL 9 MUST BE RUN AFTER CHANGING THIS PARAMETER!
  67.                
  68.            11. Also, because of the above change, MUTIL 9 must be run
  69.                immediately before running MUTIL 18 (to check node integrity)
  70.                so that the variable number of neighbors and dests can be
  71.                determined.
  72.                
  73.            12. A new USER bit has been added ($4000) to prevent the 'You
  74.                have new mail' message from being sent to a connecting
  75.                station.  This would have application in the case where you
  76.                did not wish to mark a connecting station as a bbs, when it
  77.                may be, and the lack of a '>' response may stall proper
  78.                forwarding.
  79.  
  80.            13. Automatic Sysop password reply is now implemented for
  81.                multiple MSYS systems.  The passwords are stored in the
  82.                \MSYS\FWD directory in the form: <call>.RMT   See the section
  83.                on passwords in this document for further details.
  84.                
  85.            14. The reply to sysop messages problem has been resolved.
  86.  
  87.            15. A change in the processing of R+ and \Why commands done
  88.                remotely has been made so that if the word values that caused
  89.                the hold will not be sent over the air if their values exceed
  90.                99. For example, if the word "darn" has a value of 1, the
  91.                remote read will send the word.  If the word "#$%^&" has the
  92.                value of 100 (or higher), MSYS will report instead, the type
  93.                of item (title, text, etc) and the line number in the hold
  94.                word list (BADWORDS.DAT) containing the given word.  This
  95.                will prevent the "bad" words from being retransmitted over
  96.                the air.  Processing from the local console is not changed.
  97.  
  98.  
  99.  
  100.  
  101.  
  102.  
  103.  
  104.  
  105.  
  106.  
  107.  
  108.  
  109.  
  110.  
  111.                                                                      Page  2
  112.  
  113.  
  114.  
  115.  
  116.            16. Forwarding in export format to a file is now supported. To do
  117.                so, put X0 <callsign> in the MSYSFWD.DEF file  with desired
  118.                @bbs entries.  There MUST be a digit after the  "X" - any
  119.                digit.  There must NOT be an SSID on the callsign!   A file,
  120.                <callsign>.FWD, will be created in the \MSYS directory  for
  121.                external batch forwarding.  For example:
  122.                -----------------
  123.                X1 WA8BXN
  124.                allus
  125.                ARRL
  126.                ------------------
  127.                To import messages into MSYS, use the sysop IMport command.
  128.                Messages imported this way will be checked for non-duplicate
  129.                BID numbers.
  130.                
  131.            17. A change has been made in Window 5 on the F1 screen to show
  132.                the actual station being forwarded to.
  133.  
  134.            18. A new command SYsop [ON/off] has been added.  If on, messages
  135.                to SYSOP are included in the "You have ...messages" count on
  136.                the F1 screen.
  137.                
  138.            19. Messages for MYCall will also be included in the "You have
  139.                ... messages" count.
  140.                
  141.            20. Multiple FBB proposals per packet are now implemented (as
  142.                opposed to one proposal per packet in previous versions).
  143.  
  144.  
  145.                       OTHER COMMENTS & ADDITIONS to DOCUMENTATION
  146.  
  147.  
  148.            1.  Limited bbs user.  The EditUser command includes a limited
  149.                bbs command.  Users marked with that command can do the
  150.                following:  a,b,cc,h,i,k,kt,lt,m,n,p,rm,r #,s(all forms),
  151.                t,u,v,x,?  Basically they can't do anything that produces
  152.                lots of output other than reading messages to them.
  153.                
  154.            2.  MAKE SURE there are NO BLANK LINES at end of Connect Script.
  155.                (P. 43 of MSYS 1.16 docs)
  156.                
  157.            3.  A forward connect in the MSYSFWD.DEF script that uses a
  158.                @<node> is a level 2 AX.25 connect Vs a level 3 connect
  159.                %<node>.  It WILL make a difference in the xb Vs netxb
  160.                options  (among others).
  161.                
  162.            4.  When changing the Message of the day (MSYS.OTD), you must do
  163.                a GETM from the sysop prompt or restart MSYS.  The command is
  164.                described on page 52 of the MSYS 1.16 documentation.
  165.                
  166.            5.  When changing the MSYS.REP file, you must do a REP from the
  167.                sysop prompt or restart MSYS.
  168.        
  169.  
  170.  
  171.  
  172.                                                                      Page  3
  173.  
  174.         
  175.            6.  MSYS bbs systems can beacon their geographic position for
  176.                Automatic Position Reporting Systems (APRS) usage by setting
  177.                the BT [port#] !DDMM.mmN/DDDMM.mmW$[optional info] parameter,
  178.                where DDMM.mm represents the degrees, minutes, tenths and
  179.                hundredths of minutes of their Latitude and Longitude.
  180.                The !,N/,W$ are critical symbols! For example:
  181.                      BT 0 !4108.58N/08130.16W$WB8BII BBS
  182.  
  183.  
  184.            7.  AD8I has announced that he will no longer be serving as the
  185.                MASter White Pages Server.  You may wish to enter the new 
  186.                WP server station using the MAS command in your MSYS.DO file
  187.            
  188.  
  189.                               SAM database users:
  190.  
  191.            The SAM version dated November of 1993 and called the 1994 issue
  192.            has a SAMAPI.EXE file that is 28598 bytes.  The one dated
  193.            11/23/92, is 22414 bytes.  The old one works fine with the new
  194.            database with MSYS, and will save approximately 6,000 bytes of
  195.            memory for use by MSYS.  It is possible that in a future edition,
  196.            the new version may be required to provide the add-on options.
  197.            The County option is supported by the 1992 version of SAMAPI in
  198.            MSYS.
  199.  
  200.                                        KAM RESET
  201.  
  202.            If you have problems with running MSYS PACTOR with a KAM after
  203.            using the Kamhost program, you should execute the "factory
  204.            defaults" command prior to loading MSYS.  Apparently there is
  205.            some parameter that causes premature disconnect unless the
  206.            factory defaults are used.  Also, the MSYS internal file to
  207.            initialize Kantronics tncs is called MSYSTNC.0.  There should be
  208.            no need to create a MSYSTNC.# file to initialize the present KPC-
  209.            series of tnc's.
  210.  
  211.  
  212.                                   USER BITS FOR V1SIT
  213.  
  214.            You should set the user BITS for V1SIT to $100 (at a minimum) to
  215.            prevent erroneous WP messages from being generated.  You should
  216.            also add FROM=V1SIT to your MSYSHOLD.DAT file to prevent any
  217.            unauthorized messages from being forwarded by unlicensed modem
  218.            users.
  219.  
  220.  
  221.  
  222.  
  223.  
  224.  
  225.  
  226.  
  227.  
  228.  
  229.  
  230.  
  231.  
  232.  
  233.                                                                      Page  4
  234.  
  235.  
  236.  
  237.  
  238.  
  239.                              Forwarding to AA4RE systems:
  240.  
  241.            Make sure you add the:
  242.            +to
  243.            etc. lines in your forward connect script when connecting to the
  244.            co-located BPQ node so that the [SID] will be properly received
  245.            from 4RE type systems. For example:
  246.            P0 WB2WXQ
  247.            %KPARK
  248.            +to
  249.            ?Sorry
  250.            ?with
  251.            .c bbs
  252.            $fwd/WB2WXQ.REV
  253.            ------------------------------------------
  254.  
  255.  
  256.                          Forwarding Through a PACKETEN Switch
  257.  
  258.            Here is one example of a forwarding script that allows forwarding
  259.            through a Gracilis Packet Switch.  This may not apply in all
  260.            cases, but is the script suggested by Mel, K0PFX
  261.  
  262.            R2 KD9SG
  263.            !07-23
  264.            @stl      (stl is the Gracilis switch alias)
  265.             (Carriage return sent to connect switch to port)
  266.            +Connected
  267.            ?errno
  268.            ?busy
  269.            .escape disable    (disables any "escape" characater such as
  270.            +Disabled           Ctrl X to allow compressed forwarding)
  271.            ?errno
  272.            ?busy
  273.            .C [port] [call or alias]   (Connect via Gracilis port)
  274.            +Connected
  275.            ?errno
  276.            ?busy
  277.            .C toybbs
  278.            #60
  279.            +Connected
  280.            ?Busy
  281.            ?Failed
  282.            KD9SG
  283.            $fwd\kd9sg.rev
  284.            -------
  285.  
  286.            IF compressed forwarding is not required, ".escape disable" is
  287.            not required.
  288.            Gracilis switch is model PackeTen.
  289.            Thanks to Mel, K0PFX@K0PFX
  290.  
  291.  
  292.  
  293.  
  294.  
  295.  
  296.                                                                      Page  5
  297.  
  298.  
  299.  
  300.  
  301.  
  302.                                   MSYS/MATRIX Adapter
  303.  
  304.  
  305.            Here is the latest suggestion for an adapter to interface a MSYS
  306.            serial port to a TheNet matrix.  It is suggested that this be
  307.            built into a "gender-bender" for best (and least confusing)
  308.            results.
  309.  
  310.                                         ADAPTER
  311.                         TO CPU END               TO MATRIX END
  312.                               1                        1
  313.                               2                        3
  314.                               3                        2
  315.                               5                       20
  316.                               7                        7
  317.  
  318.            In addition, add a 2.2K Ohm resistor on each end of the adapter
  319.            from pin 4 to pin 5.
  320.  
  321.  
  322.            With the above adapter, the matrix can stop MSYS from sending,
  323.            but a loss of power on MSYS will not stop the matrix data flow.
  324.            Crashes on the matrix are still possible, but seem to be
  325.            minimized by this arrangement.  Also, if you suffer from "green
  326.            screen" on the F2 screen because of data errors, make sure that
  327.            your tnc's are properly wired to the matrix.  Certain versions
  328.            use pin 4 instead of pin 20 for the request to send line.  A
  329.            jumper inside the tnc (Especially the MFJ-1270b) between pin 4
  330.            and pin 20 should resolve this problem quite easily.
  331.  
  332.  
  333.  
  334.  
  335.  
  336.  
  337.  
  338.  
  339.  
  340.  
  341.  
  342.  
  343.  
  344.  
  345.  
  346.  
  347.  
  348.  
  349.  
  350.  
  351.  
  352.  
  353.  
  354.  
  355.  
  356.  
  357.  
  358.  
  359.                                                                      Page  6
  360.  
  361.  
  362.  
  363.                                        PASSWORDS
  364.  
  365.            A new automatic password reply system has been added in MSYS for
  366.            those MSYS sysops who need to sysop multiple MSYS bbs systems
  367.            from their MSYS system.  A file with the <BBS_call>.rmt in the
  368.            \FWD directory is needed for each system for MSYS to
  369.            automatically  respond to the "Users.." command.  The
  370.            <callsign>.RMT file should be a copy of the other station's
  371.            MSYS.RMT file.  This new feature  will work with MSYS Version
  372.            1.17.  If you are sysopping an earlier version of MSYS, you will
  373.            still need to install the proper  password.rmt file in the \fwd
  374.            directory.
  375.  
  376.            Lots of confusion on which password for which application goes
  377.            where, so here's another attempt:
  378.  
  379.            PASSWORD TYPE       PASSWORD LOCATION and SAMPLE ENTRY
  380.  
  381.            User passwords      Individual FILE with password in
  382.                                directory:  c:\msys\password\<user_call>
  383.                                where file: <user_call> contains the
  384.                                password.   e.g. File W1AW contains:
  385.                                THIS.IS.MY.PASSword
  386.  
  387.            Modem passwords     LINE in file MSYSPASS.MOD   e.g.
  388.                                Joe xyzzy W1ABC
  389.  
  390.            FTP password        LINE in file MSYSPASS.DAT   e.g.
  391.                                guest * 3 c:/msys/public
  392.  
  393.            Telnet password     LINE in file MSYSPASS.IP   e.g.
  394.                                W1AW arrl W1AW
  395.  
  396.            Sysop password      FILE called MSYS.RMT in C:\MSYS directory
  397.                                THISisMYsecretPASSword   (CASE SENSITIVE!)
  398.  
  399.            Automatic           FILE(s) <callsign>.RMT in the c:\MSYS\FWD
  400.            password            directory. For example, in the file:
  401.            reply                  c:\MSYS\FWD\K8EIW.RMT
  402.                                is the password:
  403.            (MSYS will auto-       THIS-is-K8EIW-bbs-Sysop-PASSword
  404.            reply to the        and in the file:
  405.            "users" prompt IF      c:\MSYS\FWD\WA8BXN.RMT
  406.            the proper file     is the password:
  407.            is present!)           WA8BXN-bbs-Sysop-PassWORD
  408.                                ------------------------------
  409.            In the above example, the contents of the MSYS.RMT file in the
  410.            K8EIW system will be:
  411.                 THIS-is-K8EIW-bbs-Sysop-PASSword
  412.            and the contents of the MSYS.RMT in the WA8BXN system will be:
  413.                 WA8BXN-bbs-Sysop-PassWORD
  414.  
  415.            ALL password "numbers" start with position number 0 of the
  416.            phrase.  If the password is SeCreTworD, and the system asks for
  417.            a 2, a  C  is the expected response.
  418.  
  419.  
  420.  
  421.  
  422.                                                                      Page  7
  423.  
  424.  
  425.  
  426.  
  427.  
  428.                        HOW TO UPGRADE FROM MSYS1.16 to MSYS 1.17
  429.  
  430.  
  431.            The data provided on these disks is for UPGRADE of MSYS 1.16 to
  432.            MSYS 1.17 only.  For a full installation of MSYS 1.17, the three
  433.            disk set of MSYS 1.16 including the documentation is needed.  It
  434.            is available from the sources listed on page 9 of this document.
  435.  
  436.  
  437.  
  438.            1. Rename your existing MSYS.EXE file to OLDMSYS.EXE
  439.  
  440.  
  441.            2. Rename your existing MUTIL.EXE file to OLDMUTIL.EXE
  442.  
  443.  
  444.            3. Rename your existing \HELP\MSYSMSGS.DAT file to OLDMSGS.DAT
  445.  
  446.            4. Copy the new MSYSMSGS.DAT file and the *.HLP files to the
  447.               \MSYS\HELP directory.
  448.  
  449.            5. Copy the new MUTIL.EXE to the \MSYS directory.
  450.  
  451.            6. Copy the new MSYS.EXE to the \MSYS directory.
  452.  
  453.            7. Make any desired changes in the MSYS.OPT file (# of Neighbor
  454.               nodes?)and MSYS.DO (XO/NETXO, XB/NETXB, etc.)
  455.  
  456.            8. Run MUTIL 9.  ***MUST BE DONE!!!***
  457.  
  458.            9. Run MUTIL 4.  ***MUST BE DONE!!!***
  459.  
  460.           10. Start MSYS.
  461.  
  462.           11. When you are confident that things are operating properly,
  463.               feel free to delete the old files.
  464.  
  465.  
  466.  
  467.  
  468.  
  469.  
  470.  
  471.  
  472.  
  473.  
  474.  
  475.  
  476.  
  477.  
  478.  
  479.  
  480.  
  481.  
  482.  
  483.  
  484.  
  485.  
  486.  
  487.  
  488.                                                                      Page  8
  489.  
  490.  
  491.  
  492.  
  493.                                      AVAILABILITY
  494.  
  495.            MSYS is available from the Cleveland Hamnet phone BBS.  The
  496.            number is 216-942-6382.  Speed is 300 to 9600 baud.  This is a
  497.            free BBS (you pay for the call).  MSYS is also available on
  498.            coffman.csuohio.edu by anonymous ftp.  MSYS may also appear on
  499.            other systems, but these are the only ones I put it on directly.
  500.  
  501.            You may also obtain MSYS from me directly on disk (this may be
  502.            the cheapest way really and the fastest when a new version comes
  503.            out).  For US addresses the price is $5 per disk which includes
  504.            the disk, mailer and postage.  For Canadian and Mexican orders,
  505.            the price is $7.50 per disk.  For other foreign stations, the
  506.            price is $10 (US) per disk which includes Air Mail postage.
  507.  
  508.            You may order several versions at a time, I will hold your
  509.            request until the versions are released.  This way you get to be
  510.            the first Sysop on the block with the new toy!  When ordering
  511.            from me, please specify which version you already have or which
  512.            one you want.  Distribution is on 5.25 inch disks.  I keep
  513.            records with the following information for people who order MSYS,
  514.            so you may want to give me this info.  Also please indicate if
  515.            you want me to call you (collect) if it would be helpful to
  516.            answer questions you send me about MSYS.
  517.  
  518.            CALL:          Your callsign.  This is the key I use to record
  519.                           all your information.
  520.            NAME:          Where to send the disk to!
  521.            ADDR1:
  522.            ADDR2:
  523.            CITY:
  524.            STATE:
  525.            ZIP:
  526.            COUNTRY:
  527.            TELEPHONE:     If you want me to call you back (collect)
  528.            VERSION:       The version you have now
  529.            OWED:          How many you have prepaid
  530.            COMPUTER:      Speed, memory, disk space, CPU chip etc.
  531.            TNC:           Model & ROM versions
  532.            DOS:           Which version?
  533.            BBS:           BBS callsign to send you msgs .
  534.            IP:            Your IP address, if you have one
  535.  
  536.                            PLEASE NOTE THE FOLLOWING CHANGE
  537.                     (COURTESY OF YOUR U.S. POST OFFICE IN ACTION!)
  538.  
  539.            Mail requests for MSYS on disk to:
  540.                           Michael Pechura
  541.                           10809 Beechwood Drive
  542.                           Kirtland, OH 44094  (After April 15, 1994.
  543.                                               Until then:
  544.                                               Chesterland, OH 44026)
  545.  
  546.            You may call me with questions/comments at   216-256-1588.
  547.  
  548.  
  549.  
  550.  
  551.                                                                      Page  9
  552.  
  553.  
  554.  
  555.  
  556.            A stripped down version of MSYS that supports only the BBS
  557.            functions is also available.  There is no network NODe, no amtor,
  558.            no tcp/ip in this version.  You can still forward using external
  559.            network nodes, but the bbs is NOT a netrom network node!  The
  560.            KANODe is still there.  All of the BBS functions remain, along
  561.            with modem support.  Expanded memory is also still supported.
  562.            This version is called MSYSB and is available on a separate disk
  563.            or on Cleveland Hamnet.  If want to get this disk from me, it is
  564.            the same price as the others: $5 to US addresses, $7.50 to Canada
  565.            and Mexico, and $10 to other countries.
  566.  
  567.  
  568.  
  569.  
  570.  
  571.  
  572.  
  573.  
  574.  
  575.  
  576.  
  577.  
  578.  
  579.  
  580.  
  581.  
  582.  
  583.  
  584.  
  585.  
  586.  
  587.  
  588.  
  589.  
  590.  
  591.  
  592.  
  593.  
  594.  
  595.  
  596.  
  597.  
  598.  
  599.  
  600.  
  601.  
  602.  
  603.  
  604.  
  605.  
  606.  
  607.  
  608.  
  609.  
  610.  
  611.  
  612.  
  613.  
  614.                                                                      Page 10
  615.